根据故障现象,初步断定场扫描电路异常。测场输出块N301(TDA8359J)各脚电压,发现{3}脚电压为0V,正常应为15V。进一步检查发现限流R516(0.33Ω/1W)开路且变色,同时N301{3}脚对地击穿短路。更换R516、N301后试机,故障排除。 |