依次检查IC801(LC864516V)46脚中频识别信号正常,42脚行同步信号输入通路及周围元件正常,13脚AFT输入信号正常,仔细分析如果图像中频不正常,同样会出现上述故障,测VCO 9.5M压控振荡器相关引脚的电压:IC201(LA7687A)59.5M振荡输入脚、6振荡电压调整脚。结果5脚7.1V正常,6脚2.3V(正常7.1V)偏低,查R174(100Ω)变值,压控振荡器振荡频率偏离。更换后故障排除。 |