开机检查发现行管Q402击穿R426烧断.断开Q402;R426通电测+B电压正常,开机测行电流发现行电流逐渐增大,行管发热严重行激励管Q401集杨电压为75V,测IC201,OM8809,40脚电压为0.5V偏低,查外围发现R340/5.6K变为10K,换后正常。 |